CVE-2026-111735

Status: Deferred

Description

P-Net before 1.0.3 contains an integer underflow in pf_cpm_c_data_ind(). When handling a received cyclic data frame while the consumer is in the FRUN or RUN state, the offset of the APDU status was computed as the frame length minus 4 using 16-bit arithmetic, without checking that the frame is long enough. A crafted short frame makes the offset wrap around, so the function reads outside the receive buffer. This can cause a crash (denial of service) or disclose memory content.

Published
October 29, 2026 4:17 PM
Last Modified
October 29, 2026 4:26 PM
Source
4b71179a-3b92-4a9d-b9fc-af8b8ed579ee

Weaknesses (CWE)

CWE-125 CWE-191