Description

In the Linux kernel, the following vulnerability has been resolved: ALSA: hda/tas2781: Only accept CRC-less V1 data if all entries are valid Commit 408249089c48 ("ALSA: hda/tas2781: Accept V1 calibration data without CRC") only checked the first device entry. On machines where the BIOS populates fewer entries than p->ndev, the remaining all-zero entries are applied and tas2781_cali_preproc() divides by zero on playback open. Accept CRC-less V1 data only if every expected entry is non-zero and self-consistent (R0 * 1/R0 close to 1.0), otherwise reject it as before.